Skip to content

Alerting

Camera name, timestamp, incident type, the frame that triggered it with the detection highlighted, and the confidence grade from the classifier stage once available.

Channel When Notes
Guard console Every alert, immediately Local network, visual and audible
SMS to designated phones Per site configuration Sent through the on-site GSM modem
Voice call to emergency contact Critical tier only, if the site enables automatic calling Through the same modem

No consumer messaging apps are used.

A guard marks each alert Confirmed or Dismissed. Confirmed alerts can be escalated from the same screen. Resolved alerts stay on the site server for the configured retention period and are visible to the school administrator and, on request, to the operator.

Three independent checks sit between a detection and an alarm: persistence across frames, corroboration by a second model, and the classifier stage, which can stand an alarm down while keeping the event logged. Every dismissed alert can become a training example for that site.